Description

I am experiencing an error where I cannot download or use observation streams, not even for PPP or storage. The log only shows "Wrong Observations." Strangely, on another machine on the same network, I did not encounter this issue. However, I am unsure what I can do to resolve the problem on my computer.

Attachments (0)

Change History (2)

comment:1 by stuerze, 2 weeks ago

Dear Afonso,

The messages "Wrong observation epoch(s)" is reported by BNC, if the latency is larger than 600 seconds or negative. Negative values are often related to an unsynchronized computer clock on the machine, where BNC is running. Synchronizing it's clock w.r.t an external time server should help.

Nevertheless, sometimes small negative values are still available. Hence, within BNCs next version they are alos allowed. The new version will be available soon.

Best regards, Andrea

Last edited 2 weeks ago by stuerze (previous) (diff)

comment:2 by stuerze, 2 weeks ago

Resolution: fixed