Opened 2 months ago
Last modified 2 months ago
#177 needinfo defect
RTCM3.1 vs binex observables are differentes in BNC v.2.13
Reported by: | Owned by: | ||
---|---|---|---|
Priority: | normal | Component: | BNC |
Version: | Keywords: | ||
Cc: |
Description
I am getting streaming data from same Trimble NetR9 receiver but using different format, basically binex and RTCM 3.1.
The observable in rinex file that I get are differents and I can no t figure out the reason.
Could you help me, please?
Attachments (2)
Change History (3)
by , 2 months ago
Attachment: | MAR10570.24O_fromBinex added |
---|
by , 2 months ago
Attachment: | MAR10570.24O.fromRTCM added |
---|
comment:1 by , 2 months ago
Owner: | changed from | to
---|---|
Status: | new → needinfo |
Dear Ivonne,
I have no experiences with BINEX data so far but with respect to RTCM and RINEX I can say: Only the so called RTCM Multiple Signal Messages (MSM) allow a maximum compatibility with RINEX version 3/4. Lagacy RTCM messages as well as RINEX version 2 have limitations. In more detail MSM5 is able to transmit a full set of RINEX observables and MSM7 does the same with extended resolution. Maybe you can check your source format in more detail.
Best regrads, Andrea
Rinex file created from RTC streaming