Opened 8 years ago
Closed 7 years ago
#101 closed defect (fixed)
RTCM block 1092 contain partial data! Ignored!
Reported by: | sifs23 | Owned by: | stuerze |
---|---|---|---|
Priority: | normal | Component: | BNC |
Version: | Keywords: | ||
Cc: |
Description
Hello!
I am trying to get RTCM (3v) format from septentrio receiver. I get the error message (block 1092 contain partial data! Ignored!). The block that show the error are 1091,1092,1071,1072,1081 and 1082.
Could you help about how to resolve this error.
Thanks you in advance.
Note: I hope use correctly this tool.
Attachments (0)
Change History (4)
comment:1 by , 8 years ago
comment:2 by , 8 years ago
We actually support MSM types 1-3 in BNCs source code. But as they are missing
the full cycles and can't be used later we skip interpretation currently.
Best regards, Andrea.
comment:3 by , 8 years ago
Hello,
I sorry, I don't understand... Do I have to send you something or is an incompatibility between my receivers and BNC?
Thanks for your answer and sorry for don't understand (my english is not good enough)
comment:4 by , 7 years ago
Resolution: | → fixed |
---|---|
Status: | new → closed |
Hello,
Do you have a working example configuration with access to a MSM1/2 data stream?
Maybe from 2 different receiver types?
We have no MSM1 or MSM2 data stream available.
Thanks, Andrea