Changeset 3127 in ntrip for trunk/BNC/bncwindow.cpp


Ignore:
Timestamp:
Mar 24, 2011, 8:54:36 AM (13 years ago)
Author:
weber
Message:

Wording improved

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/BNC/bncwindow.cpp

    r3124 r3127  
    533533  _pppSigCLineEdit->setWhatsThis(tr("<p>Enter a sigma for your code observations in meters.</p><p>The higher the sigma you enter, the less the contribution of code observations to a PPP solution based on a combination of code and phase data. 5.0 (default) is likely to be an appropriate choice.</p>"));
    534534  _pppQuickStartLineEdit->setWhatsThis(tr("<p>Enter the lenght of a startup period in seconds for which you want to fix the PPP solution to a known XYZ coordinate as introduced above and adjust a sigma 'XYZ Ini' according to the coordinate's precision. Fixing the coordinate is done in BNC through setting the 'Sigma XYZ Noise' you define below temporarily to zero.</p><p>This so-called Quick-Start option allows the PPP solution to rapidly converge. It requires that the antenna remains unmoved on the know position throughout the startup period.</p><p>A value of 120 is likely to be an appropriate choice for 'Quick-Start'. Default is an empty option field, meaning that you don't want BNC to operate in Quick-Start mode.</p>"));
    535   _pppMaxSolGapLineEdit->setWhatsThis(tr("<p>Specify a 'Maximum Solution Gap' in seconds. Should the time span between two consecutive positioning solutions exceed this limit, the algorithm returns into the Quick-Start mode and fixes the introduced reference coordinate for the specified Quick-Start period. A value of '120' seconds could be an appropriate choice.</p><p>This option makes only sense for a stationary operated receiver where solution convergence can be enforced because the (approximate) receiver position is known. Default is an empty option field, meaning that you don't want BNC to return into the Quick-Start mode after failures caused i.e. by longer lasting outages.</p>"));
     535  _pppMaxSolGapLineEdit->setWhatsThis(tr("<p>Specify a 'Maximum Solution Gap' in seconds. Should the time span between two consecutive solutions exceed this limit, the algorithm returns into the Quick-Start mode and fixes the introduced reference coordinate for the specified Quick-Start period. A value of '120' seconds could be an appropriate choice.</p><p>This option makes only sense for a stationary operated receiver where solution convergence can be enforced because a good approximation for the receiver position is known. Default is an empty option field, meaning that you don't want BNC to return into the Quick-Start mode after failures caused i.e. by longer lasting outages.</p>"));
    536536  _pppSigPLineEdit->setWhatsThis(tr("<p>Enter a sigma for your phase observations in meters.</p><p>The higher the sigma you enter, the less the contribution of phase observations to a PPP solutions based on a combination of code and phase data. 0.02 (default) is likely to be an appropriate choice.</p>"));
    537537  _pppAverageLineEdit->setWhatsThis(tr("<p>Enter the length of a sliding time window in minutes. BNC will continuously output moving average positions computed from those individual positions obtained most recently throughout this period.</p><p>An empty option field (default) means that you don't want BNC to output moving average positions.</p>"));
Note: See TracChangeset for help on using the changeset viewer.