    r1190 r1196  
    273273  _rnxSkelLineEdit->setWhatsThis(tr("<p>Whenever BNC starts generating RINEX Observation files (and then once every day at midnight), it first tries to retrieve information needed for RINEX headers from so-called public RINEX header skeleton files which are derived from sitelogs. However, sometimes public RINEX header skeleton files are not available, its contents is not up to date, or you need to put additional/optional records in the RINEX header.</p><p>For that BNC allows using personal skeleton files that contain the header records you would like to include. You can derive a personal RINEX header skeleton file from the information given in an up to date sitelog. A file in the RINEX 'Directory' with the RINEX 'Skeleton extension' is interpreted by BNC as a personal RINEX header skeleton file for the corresponding stream.</p>"));
    274274  _rnxAppendCheckBox->setWhatsThis(tr("<p>When BNC is started, new files are created by default and any existing files with the same name will be overwritten. However, users might want to append already existing files following a restart of BNC, a system crash or when BNC crashed. Tick 'Append files' to continue with existing files and keep what has been recorded so far.</p>"));
    275   _onTheFlyComboBox->setWhatsThis(tr("<p>When operating BNC in online mode, some configuration parameters can be changed on-the-fly without interrupting the running process. For that BNC rereads parts of its configuration in pre-defined intervals.<p></p>Select '1 min', '1 hour', or '1 day' to let BNC reread its configuration every full minute, hour, or day and thus avoid usage of 'Start', 'Stop', or 'Quit' buttons.</p>"));
     275  _onTheFlyComboBox->setWhatsThis(tr("<p>When operating BNC online in 'no window' mode, some configuration parameters can be changed on-the-fly without interrupting the running process. For that BNC rereads parts of its configuration in pre-defined intervals.<p></p>Select '1 min', '1 hour', or '1 day' to force BNC to reread its configuration every full minute, hour, or day and let probably edited configuration options become effective on-the-fly without interrupting uninvolved threads.</p>"));
    276276  _rnxIntrComboBox->setWhatsThis(tr("<p>Select the length of the RINEX Observation file.</p>"));
    277277  _ephIntrComboBox->setWhatsThis(tr("<p>Select the length of the RINEX Navigation file.</p>"));