Changeset 9652 in ntrip for trunk/BNC/src/bncwindow.cpp
- Timestamp:
- Mar 11, 2022, 9:57:17 AM (2 years ago)
- File:
-
- 1 edited
Legend:
- Unmodified
- Added
- Removed
-
trunk/BNC/src/bncwindow.cpp
r9635 r9652 1507 1507 // WhatsThis, Upload Corrections 1508 1508 // ----------------------------- 1509 _uploadTable->setWhatsThis(tr("<p>BNC can upload clock and orbit corrections to Broadcast Ephemeris (Broadcast Corrections) in different SSR formats. You may have a situation where clocks and orbits come from an external Real-time Network Engine (1) or a situation where clock and orbit corrections are combined within BNC (2).</p><p>(1) BNC identifies a stream as coming from a Real-time Network Engine if its format is specified as 'RTNET' and hence its decoder string in the 'Streams' canvas is 'RTNET'. It encodes and uploads that stream to the specified Ntrip Broadcaster Host and Port</p><p>(2) BNC understands that it is expected to encode and upload combined Broadcast Ephemeris Corrections if you specify correction streams in the 'Combine Corrections' table.</p><p>To fill the 'Upload Corrections' table, hit the 'Add Row' button, double click on the 'Host' field to enter the IP or URL of an Ntrip Broadcaster and hit Enter. Select the Ntrip Version that shall be used for data upload. Then double click on the 'Port', 'Mount' and 'Password' fields to enter the Ntrip Broadcaster IP port (default is 80), the mountpoint and the stream upload password. If Ntrip Version 2 is chosen, click to the 'User' field to enter a stream upload user name. An empty 'Host' option field means that you don't want to upload corrections.</p><p>Select a target coordinate reference System (e.g. IGS14) for outgoing clock and orbit corrections.</p><p>Select a target SSR format (e.g. IGS-SSR) for outgoing clock and orbit corrections.</p><p>By default orbit and clock corrections refer to Antenna Phase Center (APC). Tick 'CoM' to refer uploaded corrections to Center of Mass instead of APC.</p><p>Specify a path for saving generated Broadcast Corrections plus Broadcast Ephemeris as SP3 orbit files. If the specified directory does not exist, BNC will not create such files. The following is a path example for a Linux system: /home/user/BNCOUTPUT${V3PROD}.sp3<br>Note that '${V3PROD}' produces the time stamp in the filename, which is related to the RINEX version 3 filename concept.</p><p>Specify a path for saving generated Broadcast Correction clocks plus Broadcast Ephemeris clocks as Clock RINEX files. If the specified directory does not exist, BNC will not create Clock RINEX files. The following is a path example for a Linux system: /home/user/BNCOUTPUT${V3PROD}.clk<br>Note that '${V3PROD}' produces the time stamp in the filename, which is related to the RINEX version 3 filename concept.</p><p>Finally, specify a SSR Provider ID (issued by RTCM), SSR Solution ID, and SSR Issue of Data number.</p><p>In case the 'Combine Corrections' table contains only one Broadcast Correction stream, BNC will add that stream content to the Broadcast Ephemeris to save results in files specified via SP3 and/or Clock RINEX file path. You should then define only the SP3 and Clock RINEX file path and no further option in the 'Upload Corrections' table. <i>[key: uploadMountpointsOut]</i></p>"));1509 _uploadTable->setWhatsThis(tr("<p>BNC can upload clock and orbit corrections to Broadcast Ephemeris (Broadcast Corrections) as well as Code Biases in different SSR formats. You may have a situation where clocks, orbits and code biases come from an external Real-time Network Engine (1) or a situation where clock and orbit corrections are combined within BNC (2).</p><p>(1) BNC identifies a stream as coming from a Real-time Network Engine if its format is specified as 'RTNET' and hence its decoder string in the 'Streams' canvas is 'RTNET'. It encodes and uploads that stream to the specified Ntrip Broadcaster Host and Port</p><p>(2) BNC understands that it is expected to encode and upload combined Broadcast Ephemeris Corrections if you specify correction streams in the 'Combine Corrections' table.</p><p>To fill the 'Upload Corrections' table, hit the 'Add Row' button, double click on the 'Host' field to enter the IP or URL of an Ntrip Broadcaster and hit Enter. Select the Ntrip Version that shall be used for data upload. Then double click on the 'Port', 'Mount' and 'Password' fields to enter the Ntrip Broadcaster IP port (default is 80), the mountpoint and the stream upload password. If Ntrip Version 2 is chosen, click to the 'User' field to enter a stream upload user name. An empty 'Host' option field means that you don't want to upload corrections.</p><p>Select a target coordinate reference System (e.g. IGS14) for outgoing clock and orbit corrections.</p><p>Select a target SSR format (e.g. IGS-SSR) for outgoing clock and orbit corrections.</p><p>By default orbit and clock corrections refer to Antenna Phase Center (APC). Tick 'CoM' to refer uploaded corrections to Center of Mass instead of APC.</p><p>Specify a path for saving generated Broadcast Corrections plus Broadcast Ephemeris as SP3 orbit files. If the specified directory does not exist, BNC will not create such files. The following is a path example for a Linux system: /home/user/BNC0SSRRTS${V3PROD}.sp3.</p><p>Specify a path for saving generated Broadcast Correction clocks plus Broadcast Ephemeris clocks as Clock RINEX files. If the specified directory does not exist, BNC will not create Clock RINEX files. The following is a path example for a Linux system: /home/user/BNC0SSRRTS${V3PROD}.clk.</p><p>Specify a path for saving generated Code Biases as SINEX Bias files. If the specified directory does not exist, BNC will not create SINEX Bias files. The following is a path example for a Linux system: /home/user/BNC0SSRRTS${V3PROD}.bia.</p><p>Note that '${V3PROD}' produces the time stamp in the filename, which is related to the RINEX version 3 filename concept.</p><p>Finally, specify a SSR Provider ID (issued by RTCM), SSR Solution ID, and SSR Issue of Data number.</p><p>In case the 'Combine Corrections' table contains only one Broadcast Correction stream, BNC will add that stream content to the Broadcast Ephemeris to save results in files specified via SP3 and/or Clock RINEX file path. You should then define only the SP3 and Clock RINEX file path and no further option in the 'Upload Corrections' table. <i>[key: uploadMountpointsOut]</i></p>")); 1510 1510 addUploadRowButton->setWhatsThis(tr("<p>Hit 'Add Row' button to add another line to the 'Upload Corrections' table.</p>")); 1511 1511 delUploadRowButton->setWhatsThis(tr("<p>Hit 'Del Row' button to delete the highlighted line(s) from the 'Upload Corrections' table.</p>")); 1512 _uploadIntrComboBox->setWhatsThis(tr("<p>Select the length of the SP3 and Clock RINEX files. <i>[key: uploadIntr]</i></p>"));1512 _uploadIntrComboBox->setWhatsThis(tr("<p>Select the length of the SP3, Clock RINEX and Bias SINEX files. <i>[key: uploadIntr]</i></p>")); 1513 1513 _uploadSamplRtcmEphCorrSpinBox->setWhatsThis(tr("<p>Select a stream's orbit correction sampling interval in seconds.</p><p>A value of zero '0' tells BNC to upload all available orbit and clock correction samples together in combined messages. <i>[key: uploadSamplRtcmEphCorr]</i></p>")); 1514 1514 _uploadSamplSp3SpinBox->setWhatsThis(tr("<p>Select a SP3 orbit file sampling interval in minutes.</p><p>A value of zero '0' tells BNC to store all available samples into SP3 orbit files. <i>[key: uploadSamplSp3]</i></p>"));
Note:
See TracChangeset
for help on using the changeset viewer.