Changeset 6907 in ntrip


Ignore:
Timestamp:
Jun 16, 2015, 12:40:26 PM (10 years ago)
Author:
weber
Message:

Typy corrected

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/BNC/src/bncwindow.cpp

    r6889 r6907  
    10731073
    10741074  _reqcSkyPlotSignals = new QLineEdit(settings.value("reqcSkyPlotSignals").toString());
    1075   _reqcSkyPlotSignals->setWhatsThis(tr("<p>BNC can produce plots for multipath, signal-to-noise ratio, satellite availability, satellite elevation, and PDOP values. The 'Plots for signals' option lets you exactly specify the observation signals to be used for that and also enables the plot production. You can specify the navigation system, the frequency, and the tracking mode or channel as defined in RINEX Version 3. Specifications for fequency and tracking mode or channel must be seperated by ampersand character '&'. Specifications for each navigation systems must be seperated by blank character ' '.</p><p>Examples for 'Plots for signals' option:<ul><li> G:1&2 R:1&2 J:1&2 E:1&7 C:1&6 S:1<br>(Plots will be based on GPS observations on 1st and 2nd frequency, GLONASS observations on 1st and 2nd frequency, QZSS observations on 1st and 2nd frequency, Galileo observations on 1st and 7th frequency, BeiDou observations on 1st and 6th frequency, SBAS observations on 1st frequency.)</li><li>G:1C&5X<br>(Plots will be based on GPS observations on 1st frequency in C tracking mode and GPS observations on 5th frequency in X tracking mode.)</li><li>C:6I&7I<br>(Plots will be based on BeiDou observations on 6th frequency in I tracking mode and BeiDou observations on 7th frequency in I tracking mode.)<li></ul></p><p>Default is 'C:1&7 E:1&5 G:1&2 J:1&2 R:1&2 S:1&5'. Specifying an empty option string would be overruled by this default.</p>"));
     1075  _reqcSkyPlotSignals->setWhatsThis(tr("<p>BNC can produce plots for multipath, signal-to-noise ratio, satellite availability, satellite elevation, and PDOP values. The 'Plots for signals' option lets you exactly specify the observation signals to be used for that and also enables the plot production. You can specify the navigation system, the frequency, and the tracking mode or channel as defined in RINEX Version 3. Specifications for fequency and tracking mode or channel must be seperated by ampersand character '&'. Specifications for each navigation systems must be seperated by blank character ' '.</p><p>Examples for 'Plots for signals' option:<ul><li> G:1&2 R:1&2 J:1&2 E:1&7 C:1&6 S:1<br>(Plots will be based on GPS observations on 1st and 2nd frequency, GLONASS observations on 1st and 2nd frequency, QZSS observations on 1st and 2nd frequency, Galileo observations on 1st and 7th frequency, BeiDou observations on 1st and 6th frequency, SBAS observations on 1st frequency.)</li><li>G:1C&5X<br>(Plots will be based on GPS observations on 1st frequency in C tracking mode and GPS observations on 5th frequency in X tracking mode.)</li><li>C:6I&7I<br>(Plots will be based on BeiDou observations on 6th frequency in I tracking mode and BeiDou observations on 7th frequency in I tracking mode.)<li></ul></p><p>Default is 'C:2&7 E:1&5 G:1&2 J:1&2 R:1&2 S:1&5'. Specifying an empty option string would be overruled by this default.</p>"));
    10761076 
    10771077  connect(_reqcSkyPlotSignals, SIGNAL(textChanged(const QString &)),
     
    10801080  _reqcLogSummaryOnly = new QCheckBox();
    10811081  _reqcLogSummaryOnly->setCheckState(Qt::CheckState(settings.value("reqcLogSummaryOnly").toInt()));
    1082   _reqcLogSummaryOnly->setWhatsThis(tr("<p>By default BNC produces a detailed 'Logfile' providing all information resulting from editing or analyzing RINEX data. If that is too much information, you can limit the logfile contents to a small summary.</p><p>Tick 'Summary only' to suppress a full logfile output and instead produce a logfile containing only summary information.</p>"));
     1082  _reqcLogSummaryOnly->setWhatsThis(tr("<p>By default BNC produces a detailed 'Logfile' providing all information resulting from editing or analyzing RINEX data. If that is too much information, you can limit the logfile contents to a short summary.</p><p>Tick 'Summary only' to suppress a full logfile output and instead produce a logfile containing only summary information.</p>"));
    10831083
    10841084  ir = 0;
Note: See TracChangeset for help on using the changeset viewer.