Changeset 2752 in ntrip
- Timestamp:
- Nov 30, 2010, 4:58:01 PM (14 years ago)
- File:
-
- 1 edited
Legend:
- Unmodified
- Added
- Removed
-
trunk/BNC/bncwindow.cpp
r2751 r2752 474 474 _pppNMEAPortLineEdit->setWhatsThis(tr("<p>Specify an IP port number to output PPP results as NMEA messages through an IP port.</p>")); 475 475 _pppSigCLineEdit->setWhatsThis(tr("<p>Enter a sigma for your code observations in meters.</p><p>The higher the sigma you enter, the less the contribution of code observations to a PPP solution based on a combination of code and phase data. 5.0 (default) is likely to be an appropriate choice.</p>")); 476 _pppQuickStartLineEdit->setWhatsThis(tr("<p>Enter the lenght of a startup period in seconds for which you want to fix the PPP solution to a known XYZ coordinate as introduced above. Fixing the coordinate is done in BNC through setting the 'XYZ White Noise' you define below temporarily to zero.</p><p>This so-called Quick-Start option allows the PPP solution to rapidly converge. It requires that the antenna remains unmoved on the know position throughout the startup period.</p><p>A value of 120 (default) is likely to be an appropriate choice for 'Quick-Start'.</p>"));476 _pppQuickStartLineEdit->setWhatsThis(tr("<p>Enter the lenght of a startup period in seconds for which you want to fix the PPP solution to a known XYZ coordinate as introduced above. Fixing the coordinate is done in BNC through setting the 'XYZ White Noise' you define below temporarily to zero.</p><p>This so-called Quick-Start option allows the PPP solution to rapidly converge. It requires that the antenna remains unmoved on the know position throughout the startup period.</p><p>A value of 120 is likely to be an appropriate choice for 'Quick-Start'. Default is an empty option field, meaning that you don't want BNC to operate in Quick-Start mode.</p>")); 477 477 _pppSigPLineEdit->setWhatsThis(tr("<p>Enter a sigma for your phase observations in meters.</p><p>The higher the sigma you enter, the less the contribution of phase observations to a PPP solutions based on a combination of code and phase data. 0.02 (default) is likely to be an appropriate choice.</p>")); 478 478 _pppAverageLineEdit->setWhatsThis(tr("<p>Enter the length of a sliding time window in minutes. BNC will continuously output moving average positions computed from those individual positions obtained most recently throughout this period.</p><p>An empty option field (default) means that you don't want BNC to output moving average positions.</p>"));
Note:
See TracChangeset
for help on using the changeset viewer.