Changeset 8130 in ntrip for branches/BNC_2.12/src/bncwindow.cpp


Ignore:
Timestamp:
Jun 12, 2017, 2:29:09 PM (7 years ago)
Author:
stuerze
Message:

undefined generation attribute '_' is added to the default signal priority string to allow editing of rinex version 2 files

File:
1 edited

Legend:

Unmodified
Added
Removed
  • branches/BNC_2.12/src/bncwindow.cpp

    r8120 r8130  
    223223  QString hlp = settings.value("rnxV2Priority").toString();
    224224  if (hlp.isEmpty()) {
    225     hlp = "G:12&PWCSLXYN G:5&IQX R:12&PC R:3&IQX E:16&BCX E:578&IQX J:1&SLXCZ J:26&SLX J:5&IQX C:IQX I:ABCX S:1&C S:5&IQX";
     225    hlp = "G:12&PWCSLXYN_ G:5&IQX_ R:12&PC_ R:3&IQX_ E:16&BCX_ E:578&IQX_ J:1&SLXCZ_ J:26&SLX_ J:5&IQX_ C:IQX_ I:ABCX_ S:1&C_ S:5&IQX_";
    226226  }
    227227  _rnxV2Priority = new QLineEdit(hlp);
     
    12491249  _rnxFileCheckBox->setWhatsThis(tr("<p>Tick check box 'Skeleton mandatory' in case you want that RINEX files are only produced if skeleton files are available for BNC. If no skeleton file is available for a particular source then no RINEX Observation file will be produced from the affected stream.</p><p>Note that a skeleton file contains RINEX header information such as receiver and antenna types. In case of stream conversion to RINEX Version 3, a skeleton file should also contain information on potentially available observation types. A missing skeleton file will therefore enforce BNC to only save a default set of RINEX 3 observation types.</p>"));
    12501250  _rnxScrpLineEdit->setWhatsThis(tr("<p>Whenever a RINEX Observation file is finally saved, you may want to compress, copy or upload it immediately, for example via FTP. BNC allows you to execute a script/batch file to carry out such operation.</p><p>Specify the full path of a script or batch file. BNC will pass the full RINEX Observation file path to the script as command line parameter (%1 on Windows systems, $1 on Unix/Linux/Mac systems).</p>"));
    1251   _rnxV2Priority->setWhatsThis(tr("<p>Specify a priority list of characters defining signal attributes as defined in RINEX Version 3. Priorities will be used to map observations with RINEX Version 3 attributes from incoming streams to Version 2. The underscore character '_' stands for undefined attributes. A question mark '?' can be used as wildcard which represents any one character.</p><p>Signal priorities can be specified as equal for all systems, as system specific or as system and freq. specific. For example: </li><ul><li>'CWPX_?' (General signal priorities valid for all GNSS) </li><li>'C:IQX I:ABCX' (System specific signal priorities for BDS and IRNSS) </li><li>'G:12&PWCSLXYN G:5&IQX R:12&PC R:3&IQX' (System and frequency specific signal priorities) </li></ul>Default is the following priority list 'G:12&PWCSLXYN G:5&IQX R:12&PC R:3&IQX E:16&BCX E:578&IQX J:1&SLXCZ J:26&SLX J:5&IQX C:IQX I:ABCX S:1&C S:5&IQX'.</p>"));
     1251  _rnxV2Priority->setWhatsThis(tr("<p>Specify a priority list of characters defining signal attributes as defined in RINEX Version 3. Priorities will be used to map observations with RINEX Version 3 attributes from incoming streams to Version 2. The underscore character '_' stands for undefined attributes. A question mark '?' can be used as wildcard which represents any one character.</p><p>Signal priorities can be specified as equal for all systems, as system specific or as system and freq. specific. For example: </li><ul><li>'CWPX_?' (General signal priorities valid for all GNSS) </li><li>'C:IQX I:ABCX' (System specific signal priorities for BDS and IRNSS) </li><li>'G:12&PWCSLXYN G:5&IQX R:12&PC R:3&IQX' (System and frequency specific signal priorities) </li></ul>Default is the following priority list 'G:12&PWCSLXYN_ G:5&IQX_ R:12&PC_ R:3&IQX_ E:16&BCX_ E:578&IQX_ J:1&SLXCZ_ J:26&SLX_ J:5&IQX_ C:IQX_ I:ABCX_ S:1&C_ S:5&IQX_'.</p>"));
    12521252  _rnxV3CheckBox->setWhatsThis(tr("<p>The default format for RINEX Observation files is RINEX Version 2.</p><p>Select 'Version 3' if you want to save observations in RINEX Version 3 format.</p>"));
    12531253  _rnxV3filenameCheckBox->setWhatsThis(tr("<p>Tick 'Version 3 filenames' to let BNC create so-called extended filenames following the RINEX Version 3 standard.</p><p>Default is an empty check box, meaning to create filenames following the RINEX Version 2 standard although the file content is saved in RINEX Version 3 format.</p>"));
Note: See TracChangeset for help on using the changeset viewer.