  • trunk/BNC/src/bncwindow.cpp

    r7046 r7051  
    898898  _pppWidgets._corrMount->setWhatsThis(tr("<p>Specify a 'mountpoint' from the 'Streams' canvas below which provides corrections to Broadcast Ephemeris.</p><p>If you don't specify a corrections stream through this option, BNC will fall back to Single Point Positioning (SPP, positioning from observations and broadcast ephemeris only only) instead of doing PPP.</p>"));
    899899
    900   _pppWidgets._crdFile->setWhatsThis(tr("<p>Enter the full path to an ASCII file which specifies the streams or files of those stations you want to process. The 'Coordinates' file must contain one record per station with the following parameters separated by blank characters:<p><ul><li>Specify the station either through<ul><li>the 'Mountpoint' of the station's RTCM stream (when in real-time PPP mode), or</li><li>the first four characters of the RINEX observations file (when in post processing PPP mode).</li></ul>This parameter is mandatory. BNC will carry out PPP solutions only for those stations which are listed here.</li><li>Approximate X,Y,Z coordinate components of station's Antenna Reference Point [m] (ARP, specify '0.0 0.0 0.0' if unknown).</li><li>Nort, East and Up component of antenna excentricity [m] (specify '0.0 0.0 0.0' if unknown).</li><li>20 Characters describing the antenna type and radome following the IGS 'ANTEX file' standard (leave blank if unknown).</li></ul></p><p>Records with exclamation mark '!' in the first column or blank records will be interpreted as comment lines and ignored.</p>"));
     900  _pppWidgets._crdFile->setWhatsThis(tr("<p>Enter the full path to an ASCII file which specifies the streams or files of those stations you want to process. Specifying a 'Coordinates' file is optional. If it exists, it should contain one record per station with the following parameters separated by blank characters:<p><ul><li>Specify the station either through<ul><li>the 'Mountpoint' of the station's RTCM stream (when in real-time PPP mode), or</li><li>the 4-charater station ID of the RINEX observations file (when in post processing PPP mode).</li></ul></li><li>Approximate X,Y,Z coordinate components of station's Antenna Reference Point [m] (ARP, specify '0.0 0.0 0.0' if unknown).</li><li>Nort, East and Up component of antenna excentricity [m] (specify '0.0 0.0 0.0' if unknown).</li><li>20 Characters describing the antenna type and radome following the IGS 'ANTEX file' standard (leave blank if unknown).</li></ul></p><p>Records with exclamation mark '!' in the first column or blank records will be interpreted as comment lines and ignored.</p>"));
    901901
    902902  _pppWidgets._antexFile->setWhatsThis(tr("<p>Observations in RTCM streams or RINEX files should be referred to the receiver's and to the satellite's Antenna Phase Center (APC) and therefore be corrected for<ul><li>Receiver APC offsets</li><li>Receiver APC variations</li><li>Satellite APC offsets.</li></ul> Specify the full path to an IGS 'ANTEX file' which contains APC offsets and variations.</p><p>If you don't specify an 'ANTEX file' then observations will not be corrected for APC offsets and variations.</p>"));