Changeset 3129 in ntrip


Ignore:
Timestamp:
Mar 24, 2011, 9:19:06 AM (13 years ago)
Author:
weber
Message:

Wording improved

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/BNC/bncwindow.cpp

    r3127 r3129  
    533533  _pppSigCLineEdit->setWhatsThis(tr("<p>Enter a sigma for your code observations in meters.</p><p>The higher the sigma you enter, the less the contribution of code observations to a PPP solution based on a combination of code and phase data. 5.0 (default) is likely to be an appropriate choice.</p>"));
    534534  _pppQuickStartLineEdit->setWhatsThis(tr("<p>Enter the lenght of a startup period in seconds for which you want to fix the PPP solution to a known XYZ coordinate as introduced above and adjust a sigma 'XYZ Ini' according to the coordinate's precision. Fixing the coordinate is done in BNC through setting the 'Sigma XYZ Noise' you define below temporarily to zero.</p><p>This so-called Quick-Start option allows the PPP solution to rapidly converge. It requires that the antenna remains unmoved on the know position throughout the startup period.</p><p>A value of 120 is likely to be an appropriate choice for 'Quick-Start'. Default is an empty option field, meaning that you don't want BNC to operate in Quick-Start mode.</p>"));
    535   _pppMaxSolGapLineEdit->setWhatsThis(tr("<p>Specify a 'Maximum Solution Gap' in seconds. Should the time span between two consecutive solutions exceed this limit, the algorithm returns into the Quick-Start mode and fixes the introduced reference coordinate for the specified Quick-Start period. A value of '120' seconds could be an appropriate choice.</p><p>This option makes only sense for a stationary operated receiver where solution convergence can be enforced because a good approximation for the receiver position is known. Default is an empty option field, meaning that you don't want BNC to return into the Quick-Start mode after failures caused i.e. by longer lasting outages.</p>"));
     535  _pppMaxSolGapLineEdit->setWhatsThis(tr("<p>Specify a 'Maximum Solution Gap' in seconds. Should the time span between two consecutive solutions exceed this limit, the algorithm returns into the Quick-Start mode and fixes the introduced reference coordinate for the specified Quick-Start period. A value of '120' seconds could be an appropriate choice.</p><p>This option makes only sense for a stationary operated receiver where solution convergence can be enforced because a good approximation for the rover position is known. Default is an empty option field, meaning that you don't want BNC to return into the Quick-Start mode after failures caused i.e. by longer lasting outages.</p>"));
    536536  _pppSigPLineEdit->setWhatsThis(tr("<p>Enter a sigma for your phase observations in meters.</p><p>The higher the sigma you enter, the less the contribution of phase observations to a PPP solutions based on a combination of code and phase data. 0.02 (default) is likely to be an appropriate choice.</p>"));
    537537  _pppAverageLineEdit->setWhatsThis(tr("<p>Enter the length of a sliding time window in minutes. BNC will continuously output moving average positions computed from those individual positions obtained most recently throughout this period.</p><p>An empty option field (default) means that you don't want BNC to output moving average positions.</p>"));
Note: See TracChangeset for help on using the changeset viewer.